Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
HLA ; 103(3): e15421, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38433722

RESUMO

Few data exist on the role of genetic factors involving the HLA system on response to Covid-19 vaccines. Moving from suggestions of a previous study investigating the association of some HLA alleles with humoral response to BNT162b2, we here compared the HLA allele frequencies among weak (n = 111) and strong (n = 123) responders, defined as those healthcare workers with the lowest and the highest anti-Spike antibody levels after vaccination. Individuals with clinical history of Covid-19 or positive anti-nucleocapside antibodies were excluded. We found the common HLA-A*03:01 allele as an independent predictor of strong humoral response (OR = 12.46, 95% CI: 4.41-35.21, p < 0.0001), together with younger age of vaccines (p = 0.004). Correlation between antibody levels and protection from breakthrough infection has been observed, with a 2-year cumulative incidence of 42% and 63% among strong and weak responders, respectively (p = 0.03). Due to the high frequency of HLA-A*03:01 and the need for seasonal vaccinations against SARS-CoV-2 mutants, our findings provide useful information about the inter-individual differences observed in humoral response after Covid-19 vaccine and might support further studies on the next seasonal vaccines.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Humanos , Infecções Irruptivas , Alelos , Vacina BNT162 , COVID-19/prevenção & controle , SARS-CoV-2 , Vacinação , Antígenos HLA-A
2.
HLA ; 103(1): e15276, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37947374

RESUMO

In an ineffective transfusion context, solid-phase immunoassays using the Luminex platform for the detection and characterization of HLA antibodies are currently used to select HLA-compatible platelet products. A new HLA antibody identification method, the HISTO SPOT® HLA AB test (BAG Health care GmbH, Lich, Germany), based on the detection of antibodies directed against a recombinant single antigen (SA) by colored spots detected by HISTO MATCH HLA AB module software, runs fully automated on the MR.SPOT®. The aim of this study was to compare the ability of the HISTO SPOT HLA AB and C1qScreen™ (C1q SAB) assays with that of the Labscreen single antigen class I (OL SAB) assay to detect anti-HLA class I antibodies in 56 serum samples from 54 platelet refractory acute myeloid leukemia patients who received HLA mismatch platelet concentrates at a single oncohematology center. In total, 1414 class I specificities, 433 HLA-A and 981 HLA-B, were detected by the OL SAB test. The mean fluorescence intensity (MFI) was >5000 for 874 antigens and <5000 for 655 antigens. The HISTO SPOT® HLA AB and C1q SAB tests identified 85% and 79% of OL SA-detected antigens with an MFI >5000, respectively, but did not identify 34% and 44% of OL SAB-detected antigens, highlighting the lower sensitivity of these techniques. Interestingly, the donor-specific antibodies (DSAs) identified by the HISTO SPOT® HLA AB and C1q SAB assays reacted against HLA mismatch platelet concentrates with the same specificity (86%) and positive predictive (77%) value as in the OL SAB test when the MFI threshold was >2000 for DSA detection. Although the HISTO SPOT® HLA AB test is less sensitive than the OL SAB test, this test could be used for the selection of HLA-compatible platelet products.


Assuntos
Complemento C1q , Isoanticorpos , Humanos , Alelos , Teste de Histocompatibilidade/métodos , Antígenos HLA , Rejeição de Enxerto
3.
HLA ; 103(1): e15203, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37632724

RESUMO

Forty-three novel HLA-H alleles, including 32 identified in cohorts of French donors for Hematopoietic Stem Cell Transplantation, have been characterized by Next-Generation Sequencing (NGS) using a long range PCR approach. A phylogenetic study confirms three main HLA-H clades.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Doadores de Tecidos , Humanos , Alelos , Filogenia , Sequenciamento de Nucleotídeos em Larga Escala , Teste de Histocompatibilidade
4.
Int J Mol Sci ; 24(22)2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-38003669

RESUMO

Lung transplantation is often complicated by acute and/or chronic rejection leading to graft-function loss. In addition to the HLA donor-specific antibodies (HLA-DSA), a few autoantibodies are correlated with the occurrence of these complications. Recently, antibodies directed against non-classical HLA molecules, HLA-G, -E, and -F have been detected in autoimmune diseases, like systemic lupus erythematosus. Non-classical HLA molecules are crucial in the immunological acceptance of the lung graft, and some of their isoforms, like HLA-G*01:04 and -G*01:06, are associated with a negative clinical outcome. The aim of this study is to determine the frequency of detection of HLA-G antibodies in lung transplant recipients (LTRs) and their impact on the occurrence of clinical complications. After incubating the cell lines SPI-801, with and without three different HLA-G isoform expression, with sera from 90 healthy blood donors and 35 LTRs (before and after transplantation), HLA-G reactivity was revealed using reagents from commercial monoclonal antibody immobilization of platelet antigen assay (MAIPA ApDIA®). Only one serum from one blood donor had specific reactivity against the HLA-G transduced lines. Non-specific reactivity in many sera from LTRs was observed with transduced- and wild-type cell lines, which may suggest recognition of an autoantigen expressed by the SPI-801 cell line. In conclusion, this study allowed the development of a specific detection tool for non-denatured HLA-G antibodies. These antibodies seem uncommon, both in healthy subjects and in complicated LTRs. This study should be extended to patients suffering from autoimmune diseases as well as kidney and heart transplant recipients.


Assuntos
Doenças Autoimunes , Transplante de Pulmão , Humanos , Antígenos HLA-G , Isoanticorpos , Prevalência , Antígenos HLA , Doadores de Tecidos , Rejeição de Enxerto , Estudos Retrospectivos
5.
Int J Mol Sci ; 24(17)2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37686397

RESUMO

Red blood cell (RBC) transfusion remains a critical component in caring for the acute and chronic complications of sickle cell disease (SCD). Patient alloimmunisation is the main limitation of transfusion, which can worsen anaemia and lead to delayed haemolytic transfusion reaction or transfusion deadlock. Although biological risk factors have been identified for immunisation, patient alloimmunisation remains difficult to predict. We aimed to characterise genetic alloimmunisation factors to optimise the management of blood products compatible with extended antigen matching to ensure the self-sufficiency of labile blood products. Considering alloimmunisation in other clinical settings, like pregnancy and transplantation, many studies have shown that HLA Ib molecules (HLA-G, -E, and -F) are involved in tolerance mechanism; these molecules are ligands of immune effector cell receptors (LILRB1, LILRB2, and KIR3DS1). Genetic polymorphisms of these ligands and receptors have been linked to their expression levels and their influence on inflammatory and immune response modulation. Our hypothesis was that polymorphisms of HLA Ib genes and of their receptors are associated with alloimmunisation susceptibility in SCD patients. The alloimmunisation profile of thirty-seven adult SCD patients was analysed according to these genetic polymorphisms and transfusion history. Our results suggest that the alloimmunisation of SCD patients is linked to both HLA-F and LILRB1 genetic polymorphisms located in their regulatory region and associated with their protein expression level.


Assuntos
Anemia Hemolítica Autoimune , Anemia Falciforme , Adulto , Feminino , Gravidez , Humanos , Receptor B1 de Leucócitos Semelhante a Imunoglobulina , Ligantes , Genes MHC Classe I , Anemia Falciforme/genética , Anemia Falciforme/terapia , Antígenos CD
6.
HLA ; 102(5): 617-619, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37602739

RESUMO

HLA-A*33:246 differs from HLA-A*33:01:01:01 allele by one nucleotide substitution in codon 135 in exon 3.

7.
HLA ; 102(5): 619-620, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37602773

RESUMO

HLA-B*07:482 differs from HLA-B*07:02:01:01 allele by one nucleotide substitution in codon 285 in exon 5.


Assuntos
Antígeno HLA-B7 , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Alelos , Éxons/genética
9.
Biology (Basel) ; 12(6)2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37372124

RESUMO

Fifty percent of all patients with cancer worldwide require radiotherapy. In the case of brain tumors, despite the improvement in the precision of radiation delivery with proton therapy, studies have shown structural and functional changes in the brains of treated patients with protons. The molecular pathways involved in generating these effects are not completely understood. In this context, we analyzed the impact of proton exposure in the central nervous system area of Caenorhabditis elegans with a focus on mitochondrial function, which is potentially implicated in the occurrence of radiation-induced damage. To achieve this objective, the nematode C. elegans were micro-irradiated with 220 Gy of protons (4 MeV) in the nerve ring (head region) using the proton microbeam, MIRCOM. Our results show that protons induce mitochondrial dysfunction, characterized by an immediate dose-dependent loss of the mitochondrial membrane potential (ΔΨm) associated with oxidative stress 24 h after irradiation, which is itself characterized by the induction of the antioxidant proteins in the targeted region, observed using SOD-1::GFP and SOD-3::GFP strains. Moreover, we demonstrated a two-fold increase in the mtDNA copy number in the targeted region 24 h after irradiation. In addition, using the GFP::LGG-1 strain, an induction of autophagy in the irradiated region was observed 6 h following the irradiation, which is associated with the up-regulation of the gene expression of pink-1 (PTEN-induced kinase) and pdr-1 (C. elegans parkin homolog). Furthermore, our data showed that micro-irradiation of the nerve ring region did not impact the whole-body oxygen consumption 24 h following the irradiation. These results indicate a global mitochondrial dysfunction in the irradiated region following proton exposure. This provides a better understanding of the molecular pathways involved in radiation-induced side effects and may help in finding new therapies.

10.
Front Immunol ; 14: 1183949, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180126

RESUMO

Background: Many studies have reported the relevance of donor-derived cfDNA (dd-cfDNA) after lung transplantation (LTx) to diagnose and monitor acute rejection (AR) or chronic rejection or infection (INF). However, the analysis of cfDNA fragment size has not been studied. The aim of this study was to determine the clinical relevance of dd-cfDNA and cfDNA size profiles in events (AR and INF) during the first month after LTx. Methods: This prospective, single-center study includes 62 LTx recipients at the Marseille Nord Hospital, France. Total cfDNA quantification was performed by fluorimetry and digital PCR, dd-cfDNA by NGS (AlloSeq cfDNA-CareDX®), and the size profile by BIABooster (Adelis®). A bronchoalveolar lavage and transbronchial biopsies at D30 established the following groups: not-injured and injured graft (AR, INF, or AR+INF). Results: Quantification of total cfDNA was not correlated with the patient's status at D30. The percentage of dd-cfDNA was significantly higher for injured graft patients at D30 (p=0.0004). A threshold of 1.72% of dd-cfDNA correctly classified the not-injured graft patients (negative predictive value of 91.4%). Among recipients with dd-cfDNA >1.72%, the quantification of small sizes (80-120bp) >3.70% identified the INF with high performance (specificity and positive predictive value of 100%). Conclusion: With the aim of considering cfDNA as a polyvalent non-invasive biomarker in transplantation, an algorithm combining the quantification of dd-cfDNA and small sizes of DNA may significantly classify the different types of allograft injuries.


Assuntos
Ácidos Nucleicos Livres , Transplante de Pulmão , Humanos , Ácidos Nucleicos Livres/genética , Estudos Prospectivos , Relevância Clínica , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/genética , Transplante de Pulmão/efeitos adversos
11.
HLA ; 101(6): 647-659, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37015889

RESUMO

Complement-dependent lymphocytotoxicity cross match (CDC-XM) is the ultimate test of donor/recipient compatibility prior to organ transplantation. This test is based on cell viability, evaluated under fluorescence microscopy by an operator after proper staining. The determination of the positivity threshold may vary depending on the operator. We developed a new method in which the final step of determining cell viability is automated using the NC-3000™ (Chemometec®), an image cytometer able to precisely determine the percentage of dead/live cells in a suspension. After T and B donor cells isolation by negative selection, complement-dependent lysis was performed in macrovolumes in a PCR plate. Then, cell viability was measured by the NC-3000™. The sensitivity and routine CDC-XM results of this new method were compared to those of CDC-XM reference method using Terasaki plates. The sensitivity of CDC-XM expressed in the ASHI scoring system of this method was similar to the reference method results for a dilution range of the positive controls. Similarly, the results of the new method were comparable in a clinical situation to those obtained with the reference method after a study of 10 cross-matches, of which 5 cross-matches with DSA were positive and five cross-matches without DSA were negative. Moreover, ASHI scores were similar to those obtained using the reference method, and the mortality percentage was reproducible (CV < 15%). The assessment of cell viability by the NC-3000™ is easy to perform and highly reproducible but requires CDC-XM to be performed by the macrovolume method. The determination of a precise percentage of viability/mortality by the automation excludes operator variability and allows a better understanding of results close to the decision threshold.


Assuntos
Transplante de Rim , Transplante de Órgãos , Humanos , Transplante de Rim/métodos , Alelos , Teste de Histocompatibilidade/métodos , Tipagem e Reações Cruzadas Sanguíneas , Proteínas do Sistema Complemento , Rejeição de Enxerto , Antígenos HLA , Isoanticorpos
12.
Blood Transfus ; 21(5): 400-408, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36795348

RESUMO

BACKGROUND: The INTERCEPTTM Blood System (Intercept Blood System, Cerus Europe BV, Amersfoort, the Netherlands) has been used to reduce or inactivate pathogen load in platelet concentrates in France for three years. MATERIALS AND METHODS: After comparing the transfusion efficiency between pathogen-reduced platelets (PR_PLT) and untreated platelet products (U_PLT), our single-center observational study assessed the effectiveness of PR_PLT for the prevention of bleeding and for therapeutic treatment of WHO grade 2 bleeding in 176 patients undergoing chemotherapy with curative intent for acute myeloid leukemia (AML). The main endpoints were the 24-hour (h) corrected count increment (24h_CCI) after each transfusion, and time to next transfusion. RESULTS: Whereas the transfused doses tended to be higher in the PR_PLT group compared to U_PLT, there was a significant difference in intertransfusion interval (ITI) and 24h_CCI. In prophylactic transfusions, PR_PLT transfusions of >0.65×1011/10 kg, regardless of the age of the product (day 2 to day 5), resulted in a 24h_CCI similar to that of the untreated platelet product; this meant the patient could be transfused at least every 48h. In contrast, most PR_PLT transfusions of <0.55×1011/10 kg did not achieve a transfusion interval of 48h. In the context of WHO grade 2 bleeding, PR_PLT transfusions >0.65×1011/10 kg and storage of less than 4 days seems more effective in stopping bleeding. DISCUSSION: These results, which must be confirmed by prospective studies, indicate the need for vigilance regarding the quantity and quality of PR_PLT products used to treat patients at risk of bleeding crisis. Future prospective studies are needed to confirm these findings.


Assuntos
Leucemia Mieloide Aguda , Transfusão de Plaquetas , Humanos , Transfusão de Plaquetas/métodos , Plaquetas , Estudos Prospectivos , Leucemia Mieloide Aguda/terapia , Hemorragia/etiologia , Hemorragia/prevenção & controle , Nonoxinol/farmacologia
13.
Front Immunol ; 14: 1023116, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36742303

RESUMO

Background: Quantification of chimerism showing the proportion of the donor in a recipient is essential for the follow-up of hematopoietic stem cell transplantation but can also be useful to document an immune tolerance situation after solid organ transplantation. Historically, chimerism has been quantified from genomic DNA, but with technological advances, chimerism from donor-derived cell-free DNA seems particularly relevant in solid organ transplantation. Methods: The reference method was until recently the short tandem repeat technique, but new innovative techniques as digital PCR (dPCR) and NGS, have revolutionized the quantification of chimerism, such as the so-called microchimerism analysis. After a short review of chimerism methods, a comparison of chimerism quantification data for two new digital PCR systems (QIAcuity™ dPCR (Qiagen®) and QuantStudio Absolute Q (ThermoFisher®) and two NGS-based chimerism quantification methods (AlloSeq HCT™ (CareDx®) and NGStrack™ (GenDX®)) was performed. Results: These new methods were correlated and concordant to routinely methods (r²=0.9978 and r²=0.9974 for dPCR methods, r²=0.9978 and r²=0.9988 for NGS methods), and had similar high performance (sensitivity, reproductibility, linearity). Conclusion: Finally, the choice of the innovative method of chimerism within the laboratory does not depend on the analytical performances because they are similar but mainly on the amount of activity and the access to instruments and computer services.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Transplante de Órgãos , Quimerismo , Quimeras de Transplante/genética , Reação em Cadeia da Polimerase/métodos
16.
Genes (Basel) ; 13(6)2022 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-35741820

RESUMO

Immunohematology laboratories are regularly facing transfusion issues due to serological weaknesses. Altered (partial) RH antigens account for most of them. In some situations, RHCE variant alleles are involved. Herein we present our three-step molecular exploration, with allele frequencies, that has efficiently untangled RH2 phenotype weaknesses and discrepancies in our 2017-2021 cohort. In the last 5 years, the PACA Corse EFS molecular platform received 265 samples from healthy blood donors or patients with C and C/e typing difficulties. The first-intention technique (DNA array and real time PCR for RHCE*CeRN research) detected RHCE variant alleles in 143 cases (54%). The RHCE alleles classically found in African populations were the most frequent, with RHCE*CeRN allele in 40 cases (15%) and (C)ces haplotype type 1 and 2 in 26 cases (10%). A "CE" effect haplotype was suspected in 56 cases, due to the uncommon DCE haplotype that may explain the low C expression. When there were no RHCE*Ce or RHCE*CE alleles, we then searched for RHD polymorphisms by DNA array. We detected the RHD*DAU5 and RHD*DIVa in 18 and 7 cases respectively, suggesting that C ambiguity is related to the presence of these alleles which has never been described with DAU5. If no variant RHCE and RHD alleles were detected, we finally sequenced the 10 exons of both RHCE and RHD genes according to the clinical context and found seven new RHCE alleles. Thus, this molecular strategy would improve the knowledge of RHCE variants' expression and, thus, optimize the transfusion management.


Assuntos
Sistema do Grupo Sanguíneo Rh-Hr , Alelos , Éxons , Frequência do Gene , Haplótipos , Humanos , Sistema do Grupo Sanguíneo Rh-Hr/genética
17.
Transfusion ; 62(8): 1643-1651, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35748562

RESUMO

BACKGROUND: Transfusion of defective platelets could contribute to the inefficiency of platelet transfusion in preventing or stopping bleeding. STUDY DESIGN AND METHODS: This single-center prospective study aimed to determine the prevalence of functional platelet abnormalities in a population of blood donors with a clinical history of bleeding diathesis or with history of hematoma (>4 cm) during blood donation. Donors with positive bleeding screening questionnaire were referred to the reference center for rare platelet diseases at La Timone University Hospital (Marseille) to confirm the bleeding tendency using a more extensive bleeding questionnaire (MCMDMscore) and to assess hemostasis, including a comprehensive platelet analysis. RESULTS: One hundred and ninety-five donors identified based on a history of hematoma and 2434 blood donors were included in the study. Eighty-eight donors (3.6%) had a bleeding score indicating a potential bleeding disorder. Five donors with a history of hematoma (2.5%) and 15 (17%) donors with a confirmed bleeding score underwent hemostatic analysis, including two men and 18 women with average age of 33.9 years. Minor hemostatic abnormalities were observed in three donors. Two donors exhibited accelerated fibrinolysis with reduced euglobulin lysis time and increased D-dimer levels in serum. Two donors had a platelet granule defect, without identification of genetic abnormality. CONCLUSION: The bleeding questionnaire proved to be a valuable tool to screen blood donors for potential platelet defects. Platelet dysfunction was rare in the blood donor population assessed. Additional studies are necessary to understand the clinical impact that the transfusion of platelets with qualitative defects has on recipients.


Assuntos
Transtornos da Coagulação Sanguínea , Transtornos Plaquetários , Transtornos Hemorrágicos , Hemostáticos , Adulto , Doadores de Sangue , Plaquetas , Feminino , Hematoma , Hemorragia/prevenção & controle , Hemostasia , Humanos , Masculino , Estudos Prospectivos
18.
Hum Immunol ; 83(6): 515-520, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35428536

RESUMO

Psoriatic arthritis (PsA) is a type of inflammatory arthritis associated with psoriasis. HLA association studies performed in northern Europe, comparing patients with control populations, have shown that the highest risk for PsA is carried by HLA-C*06, HLA-B*57 and HLA-B*27 alleles. This retrospective association study compared HLA-A, -B, -C, and -DR alleles of 500 patients from southern France, who fulfilled the CASPAR criteria for Psoriatic Arthritis (PsA), with 2346 controls from healthy blood donors, using the chi-square test. We classified PsA patients into three different subgroups according to disease: purely axial, purely peripheral and combined axial and peripheral. The 'axial' subgroup was associated with HLA-B*27 (OR = 16.3, p = 2.7 × 10-28) and its haplotypes: HLA- B*27-C*01 (OR = 12.4, p = 1.7 × 10-12) and HLA-B*27-C*02 (OR = 8.7, p = 10 × 10-9). The 'axial and peripheral' and the 'peripheral' subgroups were associated with HLA-C*06 (respectively OR = 1.5, p = 3.6 × 10-10 and OR = 2.4, p = 3.6 × 10-12) and its haplotypes HLA-C*06-B*13 (respectively OR = 2.4, p = 1.2 × 10-6 and OR = 2.8, p = 6.4 × 10-11). This association study on a southern French PsA cohort identifies HLA-C*06 as a marker for peripheral PsA and HLA-B*27 as a marker for purely axial PsA.


Assuntos
Artrite Psoriásica , Alelos , Artrite Psoriásica/epidemiologia , Artrite Psoriásica/genética , França/epidemiologia , Predisposição Genética para Doença , Antígenos HLA-A/genética , Antígenos HLA-B/genética , Antígenos HLA-C/genética , Cadeias HLA-DRB1/genética , Humanos , Estudos Retrospectivos
19.
J Transl Med ; 19(1): 15, 2021 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-33407582

RESUMO

BACKGROUND: Non-invasive molecular analysis of cell-free DNA (cfDNA) became a sensitive biomarker for monitoring organ transplantation or for detection of fetal DNA (cffDNA) in noninvasive prenatal test. In this study, we compared the efficiencies of four (semi)-automated cfDNA isolation instruments using their respective isolation kit: MagNA Pure 24 (Roche®), IDEAL (IDSolution®), LABTurbo 24 (Taigen®) and Chemagic 360 (Perkin Elmer®). The cfDNA was isolated from 5 plasma samples and the Rhesus D (RhD)-cffDNA from 5 maternal plasmas. The cfDNA were quantified by digital droplet PCR (ddPCR), BIABooster system and QUBIT fluorometer. The cfDNA fragment size profiles were assessed by BIABooster system. Chimerism were quantified by home-made ddPCR and Devyser NGS kit. RhD-cffDNA in maternal plasma were detected between weeks 14 and 24 of amenorrhea using free DNA Fetal RHD Kit® (Biorad®). RESULTS: Statistical tests have shown differences in DNA yield depending on the isolation procedure and quantification method used. Magna Pure isolates smaller cfDNA fragment size than other extraction methods (90% ± 9% vs. 74% ± 8%; p = 0.009). Chimerism was only reliable from LABTurbo 24 extractions using the NGS but not with ddPCR whatever extraction methods. RhD-cffDNA were detected by all isolation methods, although IDEAL and LABTurbo 24 systems seemed more efficient. CONCLUSIONS: This comparative study showed a dependency of cfDNA yield depending on isolation procedure and quantification method used. In total, these results suggest that the choice of pre-analytical isolation systems needs to be carefully validated in routine clinical practice.


Assuntos
Ácidos Nucleicos Livres , Teste Pré-Natal não Invasivo , Quimerismo , DNA , Feminino , Feto , Humanos , Gravidez , Diagnóstico Pré-Natal
20.
Transplant Cell Ther ; 27(1): 89.e1-89.e10, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32980546

RESUMO

Hematopoietic stem cell transplantation (HSCT) is a curative treatment for most hematologic diseases. To evaluate the level of donor engraftment, chimerism must be carefully monitored after HSCT. Short tandem repeats, quantitative PCR (qPCR), and, more recently, digital PCR (dPCR) are widely used to determine the proportions of donor and recipient cells after HSCT. The screening and quantification of chimerism have been evaluated by 2 new methods: a ready-to-use next-generation sequencing (NGS)-based method using the Devyser ChimerismNGS kit and an original combination of the Stilla crystal digital PCR (cdPCR) platform with 3-color multiplexing capacity using GenDX KMRtrack reagents. The genotyping of 4 HSCT pairs by cdPCR using 11 triplex mixes of the GenDX KMRtype kit was consistent at 98.8% with qPCR. Informative samples (n = 20) from 6 donor-recipient pairs and 1 external proficiency test demonstrated the reliability of the results (0.1% to 50%) for the 2 methods. The methods are also highly sensitive (0.1%) and accurate. The chimerism values of the 2 methods are correlated and concordant with those of the reference methods. In addition, the ADVYSER software (Devyser) is user-friendly and well adapted to chimerism monitoring. In conclusion, these 2 innovative methods are easy to perform and user-friendly in all molecular, hematology, and immunogenetic laboratories and allow the genotyping and monitoring of chimerism with high performance and sensitivity.


Assuntos
Quimerismo , Transplante de Células-Tronco Hematopoéticas , Sequenciamento de Nucleotídeos em Larga Escala , Reprodutibilidade dos Testes , Quimeras de Transplante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...